Imechapishwa: Aug 16, 2024 18:36
Advisory No: TZCERT-SA-24-0011
Source: DIR-823X - Firmware v240126
Software Affected: DIR-823X - Firmware v240126
The firmware version in the D-Link device is vulnerable to a remote command execution vulnerability. The attackers can leverage the vulnerability to take control of the affected device.
DIR-823X Hardware Revision Ax, Firmware version 240126 is affected by a LAN-Side authenticated remote command execution vulnerability resulting from improper handling of the ntp_zone_val field in the CGI request for /goform/set_ntp by the web server. craft a malicious ntp_zone_val field and send a malicious HTTP request to the /goform/set_ntp CGI, leading to command execution with administrator privileges on the firmware file system.
Successful exploitation of this vulnerability may allow an attacker to take control of the affected device.
D-Link has released a hotfix for this vulnerability. Users and administrators are encouraged to apply necessary updates.